Zsfz 150 Wet Alarm Valve China Guangbo Brand
Port:
Xiamen, China
Production Capacity:
2000 Sets Per Week
Payment Terms:
L/C, T/T, Cash Payment
Fujian Guangbo Fire Fighting Equipment Co., Ltd.
Fujian, China
Last Login Date:
Jun 30, 2025
Business Type:
Manufacturer/Factory
Main Products:
Glass Bulb Fire Sprinkler, Fusible Alloy Fire Sprinkler, Consealed Fire Sprinkler, Open Type Fire Sprinkler, Esfr Fire Sprinkler, Alarm Valve Eries, Outdoor Indoor Fire Hydrant, Fire Gate Valve Series, Multi-Purpose Fire Pump Adapter, Water Supply Valve Series
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
ZSFZ-150 Wet Alarm Valve
Alarm Valve Type
Wet Alarm Valve
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Packing
1 Set Pack by Wood Box
Packing Way
1 Set Pack as Buyer′s Requirement
Trademark
Guangbo Brand or OEM Brand
Transport Package
1 Set Pack by Standard Carton
Origin
Fujian, China
Product Description
Product Name: ZSFZ 150 Wet Alarm Valve China Guangbo Brand
1. The ZSFZ wet alarm valve is designed according to the requirements of GB5135.2-2003 "Automatic Sprinkler System Part 2: Wet Alarm Valves, Delays, and Hydraulic Alarm Bells", which only allows water to flow into the sprinkler system in one direction. It is a kind of one-way valve that drives the matching parts to alarm under the specified pressure and flow. The wet automatic sprinkler system composed of water flow indicator, pressure switch, sprinkler head, etc. is a very widely used fixed fire extinguishing system.
2. The pipe network of the system is filled with a certain pressure of clean water all year round, and it is in a working state for a long time. When a fire occurs somewhere in the protection area, the ambient temperature in the area rises. The organic matter in the heat sensitive element (glass ball) of the sprinkler The solution thermally expands and generates a great amount of internal pressure until the glass ball shell breaks, which opens the sprinkler head and sprays water, and automatically starts the entire system to emit an audible and visual alarm signal to achieve the purpose of fire alarm, fire control and fire suppression.
3. The wet alarm valve is a cover type alarm valve, which is mainly composed of a valve body, a seat ring and a valve flap. The entire valve body is divided into upper and lower chambers by the valve flap. The upper chamber (system side) communicates with the system pipe network. The lower chamber (water supply side) communicates with the water source, and a seat ring is provided in the valve body. On the seat ring, there are a plurality of grooved small holes leading to the inlet pipe of the retarder.
4. When the system is in the state of service, the small hole of the groove on the seat ring is covered and closed by the valve flap, and the alarm water channel leading to the hydraulic alarm is blocked; when the pressure difference between the upper and lower reaches a certain value, the valve flap opens ( When the differential pressure starts, the water flows from the water supply side to the system side, the alarm bell alarms, and the water spraying system sprays water; when the upper and lower pressures are frequently turned on, there is a small water supply valve on the valve flap, when the system side pipe network has a small leak Or when the pressure of the water source fluctuates, the water supply valve can be used to replenish the pipe network to balance the pressure of the upper and lower chambers and stabilize the valve flap, thereby avoiding false alarms.
Packing By Exporting Standard Carton Or Exporting Wood Box
Workshop Pictures
Exhibition Picture
Guangbo Company Create Good Brand With Trusting Fire Sprinkler ann Fire Fighting Protection Equipment, Provide Excellent Quality and Competitive Prices for Domestic and Abroad Customers. Our Business Thought is that " Quality Is Life, Protection Is Responsibility".
Thanks For Your Reading Guangbo Website, Please Send Inquiry About Fire Sprinkler and Fire Protection Equipment to Bellow Contact, Will Reply Within 24 Hours...
Wet Alarm Valve Model | ZSFZ 100 | ZSFZ 125 | ZSFZ 150 | ZSFZ 200 |
Nominal Diameter | 1.6 | 1.6 | 1.6 | 1.6 |
Sealing Pressure | 3.2 | 3.2 | 3.2 | 3.2 |
Intensity pressure | 6.4 | 6.4 | 6.4 | 6.4 |
Environmental conditions | from 4ºC until 70ºC |
Storage environment requirements | from -10ºC until +40ºC |
Storage environment | It should be stored in a ventilated and dry warehouse, avoiding storage with corrosive substances |
Product performance standards | GB5135.2-2003<Automatic sprinkler system Part 2: Wet alarm valve, delay device, hydraulic alarm bell> |
Connection method | Flanged |
Hydraulic friction | When the flow rate is 4.5m/s, Hydraulic friction<0.04MPa |
Wet Alarm Valve Details | See Below Picture |
1. The ZSFZ wet alarm valve is designed according to the requirements of GB5135.2-2003 "Automatic Sprinkler System Part 2: Wet Alarm Valves, Delays, and Hydraulic Alarm Bells", which only allows water to flow into the sprinkler system in one direction. It is a kind of one-way valve that drives the matching parts to alarm under the specified pressure and flow. The wet automatic sprinkler system composed of water flow indicator, pressure switch, sprinkler head, etc. is a very widely used fixed fire extinguishing system.
2. The pipe network of the system is filled with a certain pressure of clean water all year round, and it is in a working state for a long time. When a fire occurs somewhere in the protection area, the ambient temperature in the area rises. The organic matter in the heat sensitive element (glass ball) of the sprinkler The solution thermally expands and generates a great amount of internal pressure until the glass ball shell breaks, which opens the sprinkler head and sprays water, and automatically starts the entire system to emit an audible and visual alarm signal to achieve the purpose of fire alarm, fire control and fire suppression.
3. The wet alarm valve is a cover type alarm valve, which is mainly composed of a valve body, a seat ring and a valve flap. The entire valve body is divided into upper and lower chambers by the valve flap. The upper chamber (system side) communicates with the system pipe network. The lower chamber (water supply side) communicates with the water source, and a seat ring is provided in the valve body. On the seat ring, there are a plurality of grooved small holes leading to the inlet pipe of the retarder.
4. When the system is in the state of service, the small hole of the groove on the seat ring is covered and closed by the valve flap, and the alarm water channel leading to the hydraulic alarm is blocked; when the pressure difference between the upper and lower reaches a certain value, the valve flap opens ( When the differential pressure starts, the water flows from the water supply side to the system side, the alarm bell alarms, and the water spraying system sprays water; when the upper and lower pressures are frequently turned on, there is a small water supply valve on the valve flap, when the system side pipe network has a small leak Or when the pressure of the water source fluctuates, the water supply valve can be used to replenish the pipe network to balance the pressure of the upper and lower chambers and stabilize the valve flap, thereby avoiding false alarms.
Packing By Exporting Standard Carton Or Exporting Wood Box